On the measurement of total radiated power in uncalibrated reverberation chambers
Research output: Contribution to journal › Research article › Contributed › peer-review
Contributors
Abstract
A novel experimental procedure to measure the total radiated power of an equipment under test (EUT) placed in a reverberation chamber (RC) is presented. In contrast to the well-established method of the IEC 61000-4-21, this new procedure does not rely on information obtained during the empty chamber calibration or the calibration with the EUT in place. Thus, the method is simpler, faster, and may have a smaller uncertainty budget.
Details
Original language | English |
---|---|
Pages (from-to) | 270-279 |
Number of pages | 10 |
Journal | IEEE Transactions on Electromagnetic Compatibility |
Volume | 49 |
Issue number | 2 |
Publication status | Published - May 2007 |
Peer-reviewed | Yes |
External IDs
ORCID | /0000-0002-3894-9831/work/142252666 |
---|
Keywords
ASJC Scopus subject areas
Keywords
- Emission measurement, IEC 61000-4-21, Mode-stirred chamber, Reverberation chamber (RC), Total radiated power