On the measurement of total radiated power in uncalibrated reverberation chambers

Research output: Contribution to journalResearch articleContributedpeer-review

Contributors

Abstract

A novel experimental procedure to measure the total radiated power of an equipment under test (EUT) placed in a reverberation chamber (RC) is presented. In contrast to the well-established method of the IEC 61000-4-21, this new procedure does not rely on information obtained during the empty chamber calibration or the calibration with the EUT in place. Thus, the method is simpler, faster, and may have a smaller uncertainty budget.

Details

Original languageEnglish
Pages (from-to)270-279
Number of pages10
JournalIEEE Transactions on Electromagnetic Compatibility
Volume49
Issue number2
Publication statusPublished - May 2007
Peer-reviewedYes

External IDs

ORCID /0000-0002-3894-9831/work/142252666

Keywords

Keywords

  • Emission measurement, IEC 61000-4-21, Mode-stirred chamber, Reverberation chamber (RC), Total radiated power