On the measurement of total radiated power in uncalibrated reverberation chambers

Publikation: Beitrag in FachzeitschriftForschungsartikelBeigetragenBegutachtung

Beitragende

Abstract

A novel experimental procedure to measure the total radiated power of an equipment under test (EUT) placed in a reverberation chamber (RC) is presented. In contrast to the well-established method of the IEC 61000-4-21, this new procedure does not rely on information obtained during the empty chamber calibration or the calibration with the EUT in place. Thus, the method is simpler, faster, and may have a smaller uncertainty budget.

Details

OriginalspracheEnglisch
Seiten (von - bis)270-279
Seitenumfang10
FachzeitschriftIEEE Transactions on Electromagnetic Compatibility
Jahrgang49
Ausgabenummer2
PublikationsstatusVeröffentlicht - Mai 2007
Peer-Review-StatusJa

Externe IDs

ORCID /0000-0002-3894-9831/work/142252666

Schlagworte

Schlagwörter

  • Emission measurement, IEC 61000-4-21, Mode-stirred chamber, Reverberation chamber (RC), Total radiated power