Multiphase flow analysis using a compact gamma-ray CT system

Research output: Contribution to book/Conference proceedings/Anthology/ReportConference contributionContributedpeer-review

Contributors

Abstract

A new compact high-resolution gamma-ray computed tomography measurement system (CompaCT) for determination of phase fraction distributions in multiphase flows, occurring in technical devices with dense housings and inlets, has been developed. The obtained measurement data can be used to understand fundamental physics behind flow processes and to validate multi-phase flow models. The CompaCT contains a137Cs isotopic source and a thermally stabilized gamma-ray detector arc. Analogue and digital processing units are fully implemented within the detector. As examples, performance studies were accomplished in a steel rod bundle and a fixed bed reactor assembly.

Details

Original languageEnglish
Title of host publication7th World Congress in Industrial Process Tomography
PublisherInternational Society for Industrial Process Tomography
Pages113-120
Number of pages8
ISBN (electronic)9780853163237
Publication statusPublished - 2013
Peer-reviewedYes

Publication series

SeriesWorld Congress on Industrial Process Tomography

Conference

Title7th World Congress in Industrial Process Tomography, WCIPT7
Duration2 - 5 September 2013
CityKrakow
CountryPoland

Keywords