Multiphase flow analysis using a compact gamma-ray CT system

Publikation: Beitrag in Buch/Konferenzbericht/Sammelband/GutachtenBeitrag in KonferenzbandBeigetragenBegutachtung

Beitragende

Abstract

A new compact high-resolution gamma-ray computed tomography measurement system (CompaCT) for determination of phase fraction distributions in multiphase flows, occurring in technical devices with dense housings and inlets, has been developed. The obtained measurement data can be used to understand fundamental physics behind flow processes and to validate multi-phase flow models. The CompaCT contains a137Cs isotopic source and a thermally stabilized gamma-ray detector arc. Analogue and digital processing units are fully implemented within the detector. As examples, performance studies were accomplished in a steel rod bundle and a fixed bed reactor assembly.

Details

OriginalspracheEnglisch
Titel7th World Congress in Industrial Process Tomography
Herausgeber (Verlag)International Society for Industrial Process Tomography
Seiten113-120
Seitenumfang8
ISBN (elektronisch)9780853163237
PublikationsstatusVeröffentlicht - 2013
Peer-Review-StatusJa

Publikationsreihe

ReiheWorld Congress on Industrial Process Tomography

Konferenz

Titel7th World Congress in Industrial Process Tomography, WCIPT7
Dauer2 - 5 September 2013
StadtKrakow
LandPolen

Schlagworte

Schlagwörter

  • Computed tomography, Gamma-ray, Multi-phase flow