Einsatz von Diamantelektroden zur Brauchwassergewinnung durch elektrochemische Desinfektion von biologisch behandelten Abwässern

Research output: Contribution to journalResearch articleContributedpeer-review

Abstract

In order to prevent infections due to pathogenic germs waste water needs to be disinfected prior to reuse. In addition to membrane filtration and treatment with UV radiation electrochemical disinfection can be a suitable alternative. The use of diamond electrodes for the disinfection of waste water was investigated depending on important operational conditions and characteristics of the waste water.

Translated title of the contribution
Use of diamond electrodes for the production of servicewater by electrochemical disinfection of biologically treatedwastewater

Details

Original languageGerman
Pages (from-to)1781-1788
Number of pages8
JournalChemie-Ingenieur-Technik
Volume82
Issue number10
Publication statusPublished - Oct 2010
Peer-reviewedYes

External IDs

Scopus 77957588951
WOS 000283634800017

Keywords

Keywords

  • AOX, Diamond electrode, Electrochemical disinfection, Production of service water, Waste water treatment