Determination of 4-nonylphenol in water samples using 4-(2,6-dimethylhept-3-yl)phenol as new internal standard
Research output: Contribution to journal › Research article › Contributed › peer-review
Contributors
Abstract
A new method for determining the endocrine disrupting substance 4-nonylphenol (technical grade = mixture of isomers, 4-NP) from water samples has been developed by using 4-(2,6-dimethylhept-3-yl)phenol (4-sec-NP) as model compound. This branched monoalkylphenol is shown to serve as internal
standard (IS) for the determination of technical 4-nonylphenol. To the best of our knowledge, 4-(2,6-dimethylhept-3-yl)phenol (racemic mixture) is a newly synthesized 4-nonylphenol isomer and has not been described elsewhere. Recoveries have been determined by analyzing spiked water samples from
distilled water, river water and wastewater. Following acetylation, the compounds were enriched via solid phase extraction (SPE). Analyses of the compounds were performed by capillary column gas chromatography/
mass spectrometry (GC/MS), operating in selected ion-monitoring (SIM) mode. The recovery of technical 4-NP using either the newly prepared 4-sec-NP or 4-n-nonylphenol (4-n-NP) as IS have been compared. 4-sec-NP showed slightly better results. However, in the first series of experiments using wastewater, the yields for the derivatization of the two standard compounds were remarkably different. The yield for derivatization of 4-n-NP was approximately 20%, probably due to the difficult matrix of the wastewater. In contrast, the yield for the derivatization of 4-sec-NP was considerably higher (approximately 63%). This problem can be solved by increasing the concentration of the reagent used
for derivatization. For better control of the clean-up process, we recommend application of 4-sec-NP as internal standard, at least in water samples with complex matrices (e.g., high content of hydroxylated compounds).
standard (IS) for the determination of technical 4-nonylphenol. To the best of our knowledge, 4-(2,6-dimethylhept-3-yl)phenol (racemic mixture) is a newly synthesized 4-nonylphenol isomer and has not been described elsewhere. Recoveries have been determined by analyzing spiked water samples from
distilled water, river water and wastewater. Following acetylation, the compounds were enriched via solid phase extraction (SPE). Analyses of the compounds were performed by capillary column gas chromatography/
mass spectrometry (GC/MS), operating in selected ion-monitoring (SIM) mode. The recovery of technical 4-NP using either the newly prepared 4-sec-NP or 4-n-nonylphenol (4-n-NP) as IS have been compared. 4-sec-NP showed slightly better results. However, in the first series of experiments using wastewater, the yields for the derivatization of the two standard compounds were remarkably different. The yield for derivatization of 4-n-NP was approximately 20%, probably due to the difficult matrix of the wastewater. In contrast, the yield for the derivatization of 4-sec-NP was considerably higher (approximately 63%). This problem can be solved by increasing the concentration of the reagent used
for derivatization. For better control of the clean-up process, we recommend application of 4-sec-NP as internal standard, at least in water samples with complex matrices (e.g., high content of hydroxylated compounds).
Details
Original language | English |
---|---|
Pages (from-to) | 2950-2955 |
Journal | Journal of chromatography : including electrophoresis, mass spectrometry and other separation and detection methods : A |
Volume | 2010 |
Issue number | 1217 |
Publication status | Published - 2010 |
Peer-reviewed | Yes |
External IDs
Scopus | 77953703555 |
---|---|
ORCID | /0000-0002-4827-8146/work/142240782 |
Keywords
Keywords
- Nonylphenol isomers Internal standard Gas chromatography–mass spectrometry