In lightweight design, clinching is a cost-efficient solution as the joint is created through localized cold-forming of the joining parts. A clinch point's quality is usually assessed using ex-situ destructive testing methods. These, however, are unable to detect phenomena immediately during the joining process. For instance, elastic deformations reverse and cracks close after unloading. In-situ methods such as the force-displacement evaluation are used to control a clinching process, though deviations in the clinch point geometry cannot be derived with this method. To overcome these limitations, the clinching process can be investigated using in-situ computed tomography (in-situ CT). However, a clinching tool made of steel would cause strong artefacts and a high attenuation in the CT measurement, reducing the significance of this method. Additionally, when joining parts of the same material, the sheet-sheet interface is hardly detectable. This work aims at identifying, firstly, tool materials that allow artefact-reduced CT measurements during clinching, and, secondly, radiopaque materials that can be applied between the joining parts to enhance the detectability of the sheet-sheet interface. Therefore, both CT-suitable tool materials and radiopaque materials are selected and experimentally investigated. In the clinching process, two aluminium sheets with radiopaque material in between are clinched in a single-step (rotationally symmetric joint without cut section). It is shown that e.g. silicon nitride is suited as tool material and a tin layer is suitable to enhance the detectability of the sheet-sheet interface.
Details
Originalsprache | Englisch |
---|---|
Titel | Proceedings ESAFORM 2021 |
Erscheinungsort | Liège, Belgique |
ISBN (elektronisch) | 9782870193020 |
Publikationsstatus | Veröffentlicht - 10 Apr. 2021 |
Peer-Review-Status | Ja |
Konferenz
Titel | 24th International ESAFORM Conference on Material Forming |
---|---|
Kurztitel | ESAFORM 2021 |
Veranstaltungsnummer | 24 |
Dauer | 14 - 16 April 2021 |
Webseite | |
Bekanntheitsgrad | Internationale Veranstaltung |
Ort | online |
Stadt | Liège |
Land | Belgien |
Externe IDs
Scopus | 85104173726 |
---|---|
ORCID | /0000-0003-0014-3039/work/142233816 |
ORCID | /0000-0003-2689-1203/work/142233941 |
ORCID | /0000-0003-1370-064X/work/142243410 |
Schlagworte
Schlagwörter
- Clinching, Computed Tomography, In-situ CT, Radiopaque Material