Time reversal ultrasound focusing through multimode waveguides

Research output: Contribution to journalResearch articleContributedpeer-review

Contributors

Abstract

Ultrasound imaging in harsh environments, such as the continuous steel casting process, benefits from a spatial separation of sensors and measuring volume to avoid damaging e.g. because of high temperatures. This can be achieved through acoustical multimode waveguides. To focus ultrasound in the measuring volume despite the complex sound propagation, we propose using the time reversal technique. We present numerical simulations and experiments using the phased array ultrasound Doppler velocimeter to focus through a water filled waveguide with a 64 element array. A resolution in the millimetre range is achieved for a 68mm long waveguide.

Details

Original languageEnglish
Pages (from-to)568-574
Number of pages7
JournalTechnisches Messen
Volume84
Issue number9
Publication statusPublished - 26 Sept 2017
Peer-reviewedYes

External IDs

ORCID /0000-0002-3295-0727/work/184002734

Keywords

Keywords

  • elastodynamic finite integration technique, multimode waveguides, Phased array, time reversal