Simulation of parallel risers in the cooling-air cooler system of Siemens model Vx4.3 gas turbines at the DANTON test facility

Research output: Contribution to specialist publicationFeature article/contribution (Feuilleton)Contributedpeer-review

Contributors

Abstract

The installation of parallel risers between the cooling-air cooler and the low-pressure drum in the heat recovery steam generators used for model Vx4.3 gas turbines poses several thermohydraulic questions which could not be resolved by analysis. A test system was designed at the DANTON test facility whose configuration was based on the planned geometry of the full-scale system in order to determine through a series of experiments the thermohydraulic properties of two-phase flow in unheated, parallel risers inclined at an upward angle of 10°. The overall system operated in accordance with the principle of natural circulation.

Details

Original languageEnglish
Pages32-40
Number of pages9
Volume80
Issue number6
JournalVGB PowerTech
Publication statusPublished - 2000
Peer-reviewedYes
No renderer: customAssociatesEventsRenderPortal,dk.atira.pure.api.shared.model.researchoutput.ContributionToPeriodical

Keywords

ASJC Scopus subject areas