Performance of the ATLAS Level-1 topological trigger in Run~2

Research output: Contribution to journalResearch articleContributedpeer-review

Contributors

Abstract

During LHC Run 2 (2015–2018) the ATLAS Level-1 topological trigger allowed efficient data-taking by the ATLAS experiment at luminosities up to 2.1× 1034 cm- 2s- 1, which exceeds the design value by a factor of two. The system was installed in 2016 and operated in 2017 and 2018. It uses Field Programmable Gate Array processors to select interesting events by placing kinematic and angular requirements on electromagnetic clusters, jets, τ-leptons, muons and the missing transverse energy. It allowed to significantly improve the background event rejection and signal event acceptance, in particular for Higgs and B-physics processes.

Details

Original languageEnglish
Article number7
JournalEuropean Physical Journal C
Volume82
Issue number1
Publication statusPublished - 2022
Peer-reviewedYes

External IDs

Scopus 85122427203

Keywords

Library keywords