MRI magnitude signal-based proton beam visualisation in water phantoms reflects composite effects of beam-induced buoyant convection and radiation chemistry
Research output: Contribution to journal › Research article › Contributed › peer-review
Contributors
Abstract
Objective. Local magnetic resonance (MR) signal loss was previously observed during proton beam irradiation of free-floating water phantoms at ambient temperature using a research prototype in-beam magnetic resonance imaging (MRI) scanner. The emergence of this MR signal loss was hypothesised to be dependent on beam-induced convection. The aim of this study was therefore to unravel whether physical conditions allowing the development of convection must prevail for the beam-induced MRI signatures to emerge.Approach. The convection dependence of MRI magnitude signal-based proton beam visualisation was investigated in combined irradiation and imaging experiments using a gradient echo (GE)-based time-of-flight (ToF) angiography pulse sequence, which was first tested for its suitability for proton beam visualisation in free-floating water phantoms at ambient temperature. Subsequently, buoyant convection was selectively suppressed in water phantoms using either mechanical barriers or temperature control of water expansivity. The underlying contrast mechanism was further assessed using sagittal imaging and variation of T1 relaxation time-weighting.Main results. In the absence of convection-driven water flow, weak beam-induced MR signal changes occurred, whereas strong changes did occur when convection was not mechanically or thermally inhibited. Moreover, the degree of signal loss was found to change with the variation of T1-weighting. Consequently, beam-induced MR signal loss in free-floating water phantoms at ambient temperature does not exclusively originate from buoyant convection, but is caused by local composite effects of beam-induced motion and radiation chemistry resulting in a local change in the water T1 relaxation time.Significance. The identification of ToF angiography sequence-based proton beam visualisation in water phantoms to result from composite effects of beam-induced motion and radiation chemistry represents the starting point for the future elucidation of the currently unexplained motion-based MRI contrast mechanism and the identification of the proton beam-induced material change causing T1 relaxation time lengthening.
Details
Original language | English |
---|---|
Article number | 185002 |
Journal | Physics in medicine and biology |
Volume | 68 |
Issue number | 18 |
Publication status | Published - 8 Sept 2023 |
Peer-reviewed | Yes |
External IDs
Scopus | 85170438632 |
---|
Keywords
Keywords
- Magnetic Resonance Imaging, Phantoms, Imaging, Protons, Radioactivity, Radiochemistry