Micro- and nano-structural details of a spider's filter for substrate vibrations: Relevance for low-frequency signal transmission

Research output: Contribution to journalResearch articleContributedpeer-review

Contributors

  • Maxim Erko - , Max Planck Institute of Colloids and Interfaces (Author)
  • Osnat Younes-Metzler - , Max Planck Institute of Colloids and Interfaces (Author)
  • Alexander Rack - , European Synchrotron Radiation Facility (Author)
  • Paul Zaslansky - , Charité – Universitätsmedizin Berlin (Author)
  • Seth L. Young - , Georgia Institute of Technology (Author)
  • Garrett Milliron - , Max Planck Institute of Colloids and Interfaces (Author)
  • Marius Chyasnavichyus - , Georgia Institute of Technology (Author)
  • Friedrich G. Barth - , University of Vienna (Author)
  • Peter Fratzl - , Max Planck Institute of Colloids and Interfaces (Author)
  • Vladimir Tsukruk - , Georgia Institute of Technology (Author)
  • Igor Zlotnikov - , Max Planck Institute of Colloids and Interfaces (Author)
  • Yael Politi - , Max Planck Institute of Colloids and Interfaces (Author)

Abstract

The metatarsal lyriform organ of the Central American wandering spider Cupiennius salei is its most sensitive vibration detector. It is able to sense a wide range of vibration stimuli over four orders of magnitude in frequency between at least as low as 0.1 Hz and several kilohertz. Transmission of the vibrations to the slit organ is controlled by a cuticular pad in front of it. While the mechanism of high-frequency stimulus transfer (above ca 40 Hz) is well understood and related to the viscoelastic properties of the pad's epicuticle, it is not yet clear how low-frequency stimuli (less than 40 Hz) are transmitted. Here, we study how the pad material affects the pad's mechanical properties and thus its role in the transfer of the stimulus, using a variety of experimental techniques, such as X-ray micro-computed tomography for three-dimensional imaging, X-ray scattering for structural analysis, and atomic force microscopy and scanning electron microscopy for surface imaging. The mechanical properties were investigated using scanning acoustic microscopy and nanoindentation. We show that large tarsal deflections cause large deformation in the distal highly hydrated part of the pad. Beyond this region, a sclerotized region serves as a supporting frame which resists the deformation and is displaced to push against the slits, with displacement values considerably scaled down to only a few micrometres. Unravelling the structural arrangement in such specialized structures may provide conceptual ideas for the design of new materials capable of controlling a technical sensor's specificity and selectivity, which is so typical of biological sensors.

Details

Original languageEnglish
Article number20141111
JournalJournal of the Royal Society interface
Volume12
Issue number104
Publication statusPublished - 6 Mar 2015
Peer-reviewedYes
Externally publishedYes

External IDs

PubMed 25631567
ORCID /0000-0002-2872-8277/work/142239183

Keywords