Breakthrough behavior of granular ferric hydroxide (GFH) fixed-bed adsorption filters: Modeling and experimental approaches
Research output: Contribution to journal › Research article › Contributed › peer-review
Contributors
Abstract
Breakthrough curves (BTC) for the adsorption of arsenate and salicylic acid onto granulated ferric hydroxide (GFH) in fixed-bed adsorbers were experimentally determined and modeled using the homogeneous surface diffusion model (HSDM). The input parameters for the HSDM, the Freundlich isotherm constants and mass transfer coefficients for film and surface diffusion, were experimentally determined. The BTC for salicylic acid revealed a shape typical for trace organic compound adsorption onto activated carbon, and model results agreed well with the experimental curves. Unlike salicylic acid, arsenate BTCs showed a non-ideal shape with a leveling off at c/c0≈0.6. Model results based on the experimentally derived parameters over-predicted the point of arsenic breakthrough for all simulated curves, lab-scale or full-scale, and were unable to catch the shape of the curve. The use of a much lower surface diffusion coefficient DS for modeling led to an improved fit of the later stages of the BTC shape, pointing on a time-dependent DS. The mechanism for this time dependence is still unknown. Surface precipitation was discussed as one possible removal mechanism for arsenate besides pure adsorption interfering the determination of Freundlich constants and DS. Rapid small-scale column tests (RSSCT) proved to be a powerful experimental alternative to the modeling procedure for arsenic.
Details
| Original language | English |
|---|---|
| Pages (from-to) | 1190-1198 |
| Number of pages | 9 |
| Journal | Water Research |
| Volume | 39 |
| Issue number | 6 |
| Publication status | Published - Mar 2005 |
| Peer-reviewed | Yes |
External IDs
| Scopus | 17744374489 |
|---|---|
| PubMed | 15766974 |
Keywords
ASJC Scopus subject areas
Keywords
- Arsenic, Fixed-bed adsorption filters, Granulated ferric hydroxide, Isotherms, Mass transfer coefficients, Rapid small-scale column tests, Salicylic acid