Advanced analysis of liquid dispersion and gas-liquid mass transfer in a bubble column with dense vertical internals

Research output: Contribution to journalResearch articleContributedpeer-review

Contributors

  • Felix Möller - , Helmholtz-Zentrum Dresden-Rossendorf (Author)
  • Alan MacIsaac - , Helmholtz-Zentrum Dresden-Rossendorf (Author)
  • Yuk Man Lau - , Helmholtz-Zentrum Dresden-Rossendorf, Delft University of Technology (Author)
  • Eckhard Schleicher - , Helmholtz-Zentrum Dresden-Rossendorf (Author)
  • Uwe Hampel - , Chair of Imaging Techniques in Energy and Process Engineering (with HZDR), Helmholtz-Zentrum Dresden-Rossendorf (Author)
  • Markus Schubert - , Helmholtz-Zentrum Dresden-Rossendorf (Author)

Abstract

The influence of dense vertical tube bundles in a batch bubble column reactor (BCR) of 100 mm diameter and 1100 mm clear liquid height on liquid dispersion and gas-liquid mass transfer was studied. In particular, the effects of different tube patterns (triangular and square pitch), tube diameters (8 and 13 mm) and bottom end designs (flat and U-tube) having a tube diameter-to-pitch ratio of approx. 1.3 were investigated. Dispersion coefficients were determined based on conductive tracer experiments recorded via wire-mesh sensors (WMS) with up to 90 measurement points distributed in the column's cross-section in between the tubes. The gas-liquid mass transfer coefficient was determined via fast-responding oxygen needle probes. Tube pitch and pattern were identified as the most crucial design parameters for the extent of liquid dispersion. We found that particularly the U-tube bottom end design induces large liquid circulation patterns, which enhance dispersion. The presence of internals decreases the kla value as a consequence of turbulence damping, which is also confirmed by lower kl values (e.g. 0.6 × 10−3 m s−1 for the empty BCR and 0.25 × 10−3 m s−1 for the square pitch with 8 mm tubes at 0.05 m s−1 superficial gas velocity), whereas the pitch is the most decisive design parameter. The U-tube bottom end design was identified as the most beneficial configuration with respect to liquid mixing and gas-liquid mass transfer.

Details

Original languageEnglish
Pages (from-to)575-588
Number of pages14
JournalChemical Engineering Research and Design
Volume134
Publication statusPublished - Jun 2018
Peer-reviewedYes

Keywords

Keywords

  • 2D dispersion model, Bubble column, Gas-liquid mass transfer, Heat exchanger internals, Wire-mesh sensor