A reference architecture for condition monitoring
Research output: Contribution to book/Conference proceedings/Anthology/Report › Conference contribution › Contributed › peer-review
Contributors
Abstract
Condition monitoring and diagnostic systems support the operators of machines and plants. By these means, machine operators can run their plants efficiently, perform effective preventive maintenance and supply superordinate information systems with valid machine data. This paper describes the VDMA reference architecture for condition monitoring systems. The components of the architecture are described and their application across all levels of an automation system is shown, combining the single functions to a complete condition monitoring system.
Details
Original language | English |
---|---|
Title of host publication | 2015 IEEE World Conference on Factory Communication Systems (WFCS) |
Publisher | IEEE |
Pages | 1-8 |
Number of pages | 8 |
ISBN (print) | 978-1-4799-8244-8 |
Publication status | Published - 29 May 2015 |
Peer-reviewed | Yes |
Conference
Title | 2015 IEEE World Conference on Factory Communication Systems |
---|---|
Subtitle | Communication in Automation |
Abbreviated title | WFCS 2015 |
Conference number | 11 |
Duration | 27 - 29 May 2015 |
Website | |
City | Palma de Mallorca |
Country | Spain |
External IDs
Scopus | 84942274920 |
---|---|
ORCID | /0000-0002-4646-4455/work/163764057 |
Keywords
Keywords
- Condition monitoring, Automation, Monitoring, Industries, Industrial communication, Guidelines