Outcomes Beyond 10 Years After Transcatheter Aortic Valve Implantation in High-Risk Patients With Severe Aortic Valve Stenosis

Publikation: Beitrag in Fachzeitschrift › Forschungsartikel › Beigetragen › Begutachtung

Beitragende

  • Ellen Dietze - , Herzzentrum Leipzig (Autor:in)
  • Ines Richter - , Herzzentrum Leipzig (Autor:in)
  • Oliver Dumpies - , Herzzentrum Leipzig (Autor:in)
  • Johannes Rotta Detto Loria - , Herzzentrum Leipzig (Autor:in)
  • Nicolas Majunke - , Herzzentrum Leipzig (Autor:in)
  • Hans-Josef Feistritzer - , Herzzentrum Leipzig (Autor:in)
  • Philipp Kiefer - , Herzzentrum Leipzig (Autor:in)
  • David Holzhey - , Herzzentrum Leipzig (Autor:in)
  • Thilo Noack - , Herzzentrum Leipzig (Autor:in)
  • Axel Linke - , Klinik für Innere Medizin und Kardiologie (am Herzzentrum) (Autor:in)
  • Norman Mangner - , Klinik für Innere Medizin und Kardiologie (am Herzzentrum) (Autor:in)
  • Steffen Desch - , Herzzentrum Leipzig (Autor:in)
  • Michael Borger - , Herzzentrum Leipzig (Autor:in)
  • Holger Thiele - , Herzzentrum Leipzig (Autor:in)
  • Mohamed Abdel-Wahab - , Herzzentrum Leipzig (Autor:in)

Abstract

BACKGROUND: Limited data is available on long-term outcomes and valve durability measures of transcatheter aortic valve implantation (TAVI).

AIMS: This study sought to assess clinical and echocardiographic outcomes of high-risk patients during the early experience of TAVI with a follow-up period extending beyond 10 years.

METHODS: Patients were included who had undergone TAVI at the Heart Center Leipzig between 2006 and 2012. Valve durability measures including moderate and severe structural valve deterioration (SVD) were defined according to the updated standardized definitions of the Valve Academic Research Consortium 3 (VARC-3).

RESULTS: A total of 1825 patients were included. The 12-year mortality rate was 92.8%. At 12 years post-TAVI, the cumulative incidence of SVD was 9.8% in the total population. Complete echocardiographic follow-up at ≥ 9 years was available for 56 patients. The median follow-up of this subgroup was 10.0 years. Moderate SVD was observed in three patients of the echocardiographic follow-up cohort (5.4%) and severe SVD in two patients (3.6%). Self-expanding (SE) transcatheter heart valves (THV) had a significantly lower rate of any SVD (2.8% vs 20.0%, p = 0.030) than balloon-expandable (BE) THV.

CONCLUSION: Long-term mortality rates in high-risk patients treated with TAVI more than 10 years ago are substantial, which limits assessment of valve durability measures. In a subgroup of survivors beyond 9 years, the cumulative incidence of SVD was low.

Details

OriginalspracheEnglisch
Seiten (von - bis)1301-1309
Seitenumfang9
FachzeitschriftCatheterization and Cardiovascular Interventions
Jahrgang106
Ausgabenummer2
PublikationsstatusVeröffentlicht - 1 Aug. 2025
Peer-Review-StatusJa

Externe IDs

PubMedCentral PMC12336767
Scopus 105008205185

Schlagworte

Schlagwörter

  • Humans, Aortic Valve Stenosis/mortality, Male, Female, Time Factors, Treatment Outcome, Aged, 80 and over, Transcatheter Aortic Valve Replacement/adverse effects, Risk Factors, Severity of Illness Index, Aortic Valve/diagnostic imaging, Aged, Heart Valve Prosthesis, Germany/epidemiology, Risk Assessment, Prosthesis Design, Retrospective Studies, Prosthesis Failure