Impedimetrischer Inline-Biofilmsensor

Publikation: Beitrag in FachzeitschriftForschungsartikelBeigetragenBegutachtung

Beitragende

  • Annekatrin Delan - , Professur für Festkörperelektronik (Autor:in)
  • Michael Becker - , 4H-JENA engineering GmbH (Autor:in)
  • Michael Boer - , 4H-JENA engineering GmbH (Autor:in)
  • Klaus Liefeith - , Institut für Bioprozess- und Analysenmesstechnik e.V. (IBA) (Autor:in)
  • Marion Frant - , Institut für Bioprozess- und Analysenmesstechnik e.V. (IBA) (Autor:in)
  • Jurgen Rost - , Institut für Bioprozess- und Analysenmesstechnik e.V. (IBA) (Autor:in)
  • Uwe Schirmer - , Institut für Bioprozess- und Analysenmesstechnik e.V. (IBA) (Autor:in)
  • Christian Pietsch - , 3Faktur GmbH (Autor:in)
  • Daniel Glob - , Fraunhofer-Institut für Organische Elektronik, Elektronenstrahl- und Plasmatechnik (Autor:in)
  • Margarita Gunther - , Professur für Festkörperelektronik (Autor:in)
  • Gerald Gerlach - , Professur für Festkörperelektronik (Autor:in)

Abstract

In this paper, a novel sensor system for the detection of bacterial contamination in drinking water supply equipment and in technical water recirculation systems is presented, which allows a permanent monitoring of the drinking water piping. The implemented measuring system is based on the two-sensors principle with the main sensor containing a porous polyamide substrate trap serving as a trap for microorganisms, which can grow and build a biofilm, and a reference sensor. The three-dimensional structure of the substrate trap was designed and implemented by means of additive manufacturing. As a result, it was possible to find an optimal compromise between fluidically optimized 3D structure and technological feasibility using 3D printing. The sensor was connected to a process measuring and control unit using a data interface. This enabled the comparison of the impedimetric signals of the measuring and reference channels as well as a difference signal output. The antibacterial treatment of the water recirculation components should be performed if the difference signal of the sensor exceeds a given threshold value. This early maintenance prevents a health threat due to water contamination. The sensor system is designed as an interchangeable unit. Its components fulfil the hygienic requirements of the Drinking Water Guidelines for the use in drinking water piping.

Details

OriginalspracheDeutsch
Seiten (von - bis)835-846
Seitenumfang12
FachzeitschriftTechnisches Messen
Jahrgang89
Ausgabenummer12
PublikationsstatusVeröffentlicht - 1 Dez. 2022
Peer-Review-StatusJa

Externe IDs

ORCID /0000-0002-7062-9598/work/174430572

Schlagworte

Schlagwörter

  • bacterial contamination of the drinking water piping, biofilm, Biosensor for environmental monitoring, fluorescence microscopy, impedance spectroscopy