Comparative 30-day echocardiographic outcomes of Myval vs. Sapien and Evolut THVs: Insights from LANDMARK Trial

Publikation: Beitrag in FachzeitschriftForschungsartikelBeigetragenBegutachtung

Beitragende

  • Osama Soliman - , Cardiovascular Research Institute Dublin (CVRI) (Autor:in)
  • Elfatih A Hasabo - , Cardiovascular Research Institute Dublin (CVRI) (Autor:in)
  • Niels van Royen - , Radboud University Medical Center (Autor:in)
  • Ignacio J Amat-Santos - , Hospital Clínico Universitario de Valladolid (Autor:in)
  • Martin Hudec - , Central Slovak Institute of Heart and Vascular Diseases (Autor:in)
  • Matjaz Bunc - , University Medical Centre Ljubljana (Autor:in)
  • Alexander IJsselmuiden - , Zuyderland Ziekenhuis (Autor:in)
  • Peep Laanmets - , North Estonia Medical Centre (Autor:in)
  • Daniel Unic - , Klinička bolnica Dubrava (Autor:in)
  • Bela Merkely - , Semmelweis University (Autor:in)
  • Renicus S Hermanides - , Isala Klinieken Zwolle (Autor:in)
  • Mohamed Mouden - , European Interbalkan Medical Center Thessaloniki (Autor:in)
  • Vlasis Ninios - , European Interbalkan Medical Center Thessaloniki (Autor:in)
  • Marcin Protasiewicz - , Wrocław Medical University (Autor:in)
  • Benno J W M Rensing - , St. Antonius Ziekenhuis (Autor:in)
  • Pedro L Martin - , Hospital Universitario de Gran Canaria Doctor Negrín (Autor:in)
  • Fausto Feres - , Instituto Dante Pazzanese de Cardiologia (Autor:in)
  • Manuel De Sousa Almeida - , Universidade NOVA de Lisboa (Autor:in)
  • Eric van Belle - , Centre Hospitalier Universitaire (CHU) de Lille (Autor:in)
  • Axel Linke - , Klinik für Innere Medizin und Kardiologie (am Herzzentrum) (Autor:in)
  • Alfonso Ielasi - , IRCCS Ospedale Galeazzi - Sant'Ambrogio (Autor:in)
  • Matteo Montorfano - , IRCCS Ospedale San Raffaele - Milano (Autor:in)
  • Mark Webster - , Auckland City Hospital (Autor:in)
  • Konstantinos Toutouzas - , Hippokration General Hospital — Athens (Autor:in)
  • Emmanuel Teiger - , Hôpital Henri Mondor (Autor:in)
  • Francesco Bedogni - , IRCCS Policlinico San Donato (Autor:in)
  • Michiel Voskuil - , Universitätsklinikum Utrecht (Autor:in)
  • Dolores Mesa Rubio - , Hospital Universitario Reina Sofía, Maimónides Institute of Biomedical Research of Cordoba (IMIBIC), CIBER - Enfermedades Cardiovasculares (CIBERCV) (Autor:in)
  • Oskar Angerås - , University of Gothenburg (Autor:in)
  • Won-Keun Kim - , Kerckhoff Klinik (Autor:in)
  • Jürgen Rothe - , Universitätsklinikum Freiburg (Autor:in)
  • Ivica Kristić - , Klinički Bolnički Centar (KBC) Split (Autor:in)
  • Vicente Peral - , Fundació Institut d'Investigació Sanitaria Illes Balears (Autor:in)
  • Ben J L Van den Branden - , Amphia Hospital (Autor:in)
  • Ashokkumar Thakkar - , Meril Life Sciences Pvt. Ltd. (Autor:in)
  • Udita Chandra - , Meril Life Sciences Pvt. Ltd. (Autor:in)
  • Dina Neiroukh - , Cardiovascular Research Institute Dublin (CVRI) (Autor:in)
  • Cagri Ayhan - , Cardiovascular Research Institute Dublin (CVRI) (Autor:in)
  • Mahmoud Y Nosir - , University Hospital Galway (Autor:in)
  • Magdi S Yacoub - , Cardiovascular Research Institute Dublin (CVRI) (Autor:in)
  • Sanaa Ali - , Cardiovascular Research Institute Dublin (CVRI) (Autor:in)
  • Mohamad Altamimi - , Cardiovascular Research Institute Dublin (CVRI) (Autor:in)
  • Hesham Elzomor - , University Hospital Galway (Autor:in)
  • Patrick W Serruys - , University Hospital Galway (Autor:in)
  • Andreas Baumbach - , Cleveland Clinic London (Autor:in)

Abstract

INTRODUCTION: Several factors, including device design, annulus size, and sizing strategies, influence transcatheter heart valve (THV) hemodynamic outcomes in patients with aortic stenosis(AS). This substudy evaluates early (30-day) echocardiographic outcomes of the Myval, Sapien, and Evolut THV series, focusing on hemodynamic performance and valve durability.

METHODOLOGY: The LANDMARK trial is a prospective, randomised, multicentre, open-label, non-inferiority trial comparing 384 patients implanted with Myval THV series to 384 receiving Sapien and Evolut THV series. Hemodynamic assessments followed Valve Academic Research Consortium-3 recommendations.

RESULTS: At 30-day, hemodynamic device success rates were 85.9%, 77.8, and 85.4% for Myval, Sapien, and Evolut THV series, respectively (PMyval-Sapien=0.02 and PMyval-Evolut>0.99). Significant improvements in peak aortic flow velocity, pressure gradients, effective orifice area(EOA), Doppler velocity index(DVI), and cardiac indices were observed across all groups, except for unchanged left ventricular ejection fraction. Moderate prosthesis-patient mismatch (PPM) was less frequent with Myval THV series(10.7%) versus Sapien THV series(22.5%), but higher than Evolut THV series (6.0%)(PMyval-Sapien=0.0006, PMyval-Evolut=0.12), while severe PPM showed no significant differences(4.3% vs 6.5% vs 1.8%; PMyval-Sapien=0.40, PMyval-Evolut=0.23). Total aortic regurgitation (≥moderate) showed no significant difference for Myval (2.6%), Sapien(1.8%) or Evolut THV series (6.3%)(PMyval-Sapien=0.76, PMyval-Evolut=0.06). Myval THV series required minimal oversizing compared to Evolut THV series (P<0.0001).

CONCLUSION: The Myval THV series demonstrates short-term hemodynamic performance comparable to Evolut THV series and superior to Sapien THV series in moderate PPM incidence. Including intermediate sizes minimizes oversizing, underscoring its potential as an alternative for TAVI patients. Long-term follow-up is necessary to confirm these findings.

Details

OriginalspracheEnglisch
Seiten (von - bis)247-260
Seitenumfang14
FachzeitschriftEuropean heart journal. Cardiovascular imaging
Jahrgang27
Ausgabenummer2
Frühes Online-Datum28 Aug. 2025
PublikationsstatusVeröffentlicht - Feb. 2026
Peer-Review-StatusJa

Externe IDs

unpaywall 10.1093/ehjci/jeaf245
Scopus 105029715348

Schlagworte

Schlagwörter

  • Aged, Aged, 80 and over, Aortic Valve Stenosis/surgery, Echocardiography, Doppler/methods, Echocardiography/methods, Female, Heart Valve Prosthesis, Hemodynamics/physiology, Humans, Male, Prospective Studies, Prosthesis Design, Time Factors, Transcatheter Aortic Valve Replacement/methods, Treatment Outcome, non-inferiority, echocardiography, TAVI, PPM, stenosis, aortic stenosis, balloon expandable BEV, Myval, aortic valve, THV, haemodynamic, randomized trial, transcatheter heart valve, self expandable SEV, aortic regurgitation, Evolut, Sapien