Tumour bed irradiation of human tumour xenografts in a nude rat model using a common X-ray tube
Publikation: Beitrag in Fachzeitschrift › Forschungsartikel › Beigetragen › Begutachtung
Beitragende
Abstract
Studies that investigate the radiation of human tumour xenografts require an appropriate radiation source and highly standardized conditions during radiation. This work reports on the design of a standardized irradiation device using a commercially available X-ray tube with a custom constructed lead collimator with two circular apertures and an animal bed plate, permitting synchronous irradiation of two animals. Dosimetry and the corresponding methodology for radiotherapy of human non-small cell lung cancer xenograft tumours transplanted to and growing subcutaneously on the right lower limb in a nude rat model were investigated. Procedures and results described herein prove the feasibility of use of the device, which is applicable for any investigation involving irradiation of non-tumorous and tumorous lesions in small animals.
Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 203-207 |
Seitenumfang | 5 |
Fachzeitschrift | Journal of Biosciences |
Jahrgang | 35 |
Ausgabenummer | 2 |
Publikationsstatus | Veröffentlicht - Juni 2010 |
Peer-Review-Status | Ja |
Externe IDs
PubMed | 20689176 |
---|
Schlagworte
Ziele für nachhaltige Entwicklung
ASJC Scopus Sachgebiete
Schlagwörter
- Human tumour xenografts, Radiation, Rats, Tumour bed