Topology optimization of fluid cooling systems for machine tools

Publikation: Beitrag zu KonferenzenPaperBeigetragenBegutachtung

Abstract

Fluid cooling systems for machine tools commonly
operate with a constant speed drive pump and manual valves.
The volume flow rate for cooling the components is set to a
fixed value during commissioning and is not changed by the user
during operation. Recent research propose temperature control
for machine tools. This requires variable speed drive pumps or
proportional valves. A major obstacle to implementing such a
system are material costs. This paper presents a method for
designing such a systems with minimal costs.

Details

OriginalspracheEnglisch
PublikationsstatusVeröffentlicht - 2022
Peer-Review-StatusJa

Konferenz

TitelGlobal Fluid Power Society PhD Symposium 2022
KurztitelGFPS PhD Symposium 2022
Dauer12 - 14 Oktober 2022
OrtUniversity of Naples
StadtNaples
LandItalien

Externe IDs

ORCID /0000-0001-7612-0357/work/142237280

Schlagworte

Schlagwörter

  • optimization, machine tools, cooling systems, compensation, variable speed pumps, simulation, temperature (field), cost