The potential for clinical application of automatic quantification of olfactory bulb volume in MRI scans using convolutional neural networks

Publikation: Beitrag in FachzeitschriftForschungsartikelBeigetragenBegutachtung

Beitragende

Abstract

The olfactory bulbs (OBs) play a key role in olfactory processing; their volume is important for diagnosis, prognosis and treatment of patients with olfactory loss. Until now, measurements of OB volumes have been limited to quantification of manually segmented OBs, which is a cumbersome task and makes evaluation of OB volumes in large scale clinical studies infeasible. Hence, the aim of this study was to evaluate the potential of our previously developed automatic OB segmentation method for application in clinical practice and to relate the results to clinical outcome measures. To evaluate utilization potential of the automatic segmentation method, three data sets containing MR scans of patients with olfactory loss were included. Dataset 1 (N = 66) and 3 (N = 181) were collected at the Smell and Taste Center in Ede (NL) on a 3 T scanner; dataset 2 (N = 42) was collected at the Smell and Taste Clinic in Dresden (DE) on a 1.5 T scanner. To define the reference standard, manual annotation of the OBs was performed in Dataset 1 and 2. OBs were segmented with a method that employs two consecutive convolutional neural networks (CNNs) that the first localize the OBs in an MRI scan and subsequently segment them. In Dataset 1 and 2, the method accurately segmented the OBs, resulting in a Dice coefficient above 0.7 and average symmetrical surface distance below 0.3 mm. Volumes determined from manual and automatic segmentations showed a strong correlation (Dataset 1: r = 0.79, p < 0.001; Dataset 2: r = 0.72, p = 0.004). In addition, the method was able to recognize the absence of an OB. In Dataset 3, OB volumes computed from automatic segmentations obtained with our method were related to clinical outcome measures, i.e. duration and etiology of olfactory loss, and olfactory ability. We found that OB volume was significantly related to age of the patient, duration and etiology of olfactory loss, and olfactory ability (F(5, 172) = 11.348, p < 0.001, R 2 = 0.248). In conclusion, the results demonstrate that automatic segmentation of the OBs and subsequent computation of their volumes in MRI scans can be performed accurately and can be applied in clinical and research population studies. Automatic evaluation may lead to more insight in the role of OB volume in diagnosis, prognosis and treatment of olfactory loss.

Details

OriginalspracheEnglisch
Aufsatznummer103411
Seiten (von - bis)103411
FachzeitschriftNeuroImage. Clinical
Jahrgang38
PublikationsstatusElektronische Veröffentlichung vor Drucklegung - 25 Apr. 2023
Peer-Review-StatusJa

Externe IDs

Scopus 85158850222
ORCID /0000-0001-9713-0183/work/146645610

Schlagworte

Schlagwörter

  • Convolutional neural networks, Deep learning, Olfactory bulb volume, Olfactory loss, Segmentation, Neural Networks, Computer, Humans, Magnetic Resonance Imaging/methods, Olfactory Bulb/diagnostic imaging, Smell