The Felsenkeller shallow-underground laboratory for nuclear astrophysics

Publikation: Beitrag in FachzeitschriftForschungsartikelBeigetragenBegutachtung

Beitragende

  • Daniel Bemmerer - , Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Autor:in)
  • Axel Boeltzig - , Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Autor:in)
  • Marcel Grieger - , Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Autor:in)
  • Katharina Gudat - , Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Autor:in)
  • Thomas Hensel - , Professur für Kernphysik, Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Autor:in)
  • Eliana Masha - , Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Autor:in)
  • Max Osswald - , Professur für Kernphysik, Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Autor:in)
  • Bruno Poser - , Helmholtz-Zentrum Dresden-Rossendorf (HZDR), Technische Universität Dresden (Autor:in)
  • Simon Rümmler - , Institut für Kern- und Teilchenphysik (IKTP), Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Autor:in)
  • Konrad Schmidt - , Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Autor:in)
  • José Luis Taín - , University of Valencia (Autor:in)
  • Ariel Tarifeño-Saldivia - , University of Valencia, UPC Universitat Politècnica de Catalunya (Barcelona Tech) (Autor:in)
  • Steffen Turkat - , Professur für Kernphysik (Autor:in)
  • Anup Yadav - , Professur für Kernphysik, Helmholtz-Zentrum Dresden-Rossendorf (HZDR) (Autor:in)
  • Kai Zuber - , Professur für Kernphysik (Autor:in)

Abstract

In the Felsenkeller shallow-underground site, protected from cosmic muons by a 45 m thick rock overburden, a research laboratory including a 5 MV Pelletron ion accelerator and a number of radioactivity-measurement setups is located. The laboratory and its installations are described in detail. The background radiation has been studied, finding suppression factors of 40 for cosmic-ray muons, 200 for ambient neutrons, and 100 for the background in germanium γ-ray detectors. Using an additional active muon veto, typically the background is just twice as high as in very deep underground laboratories. The properties of the accelerator including its external and internal ion sources and beam line are given. For the radioactivity counting setup, detection limits in the 10-4 Bq range have been obtained. Practical aspects for the usage of the laboratory by outside scientific users are discussed.

Details

OriginalspracheEnglisch
Aufsatznummer19
FachzeitschriftEuropean Physical Journal A
Jahrgang61
Ausgabenummer1
PublikationsstatusVeröffentlicht - Jan. 2025
Peer-Review-StatusJa

Externe IDs

Scopus 85218417667
ORCID /0000-0002-0509-8743/work/180881643

Schlagworte

ASJC Scopus Sachgebiete

Schlagwörter

  • physics.ins-det, nucl-ex