Studies of indium tin oxide-based sensing electrodes in potentiometric zirconia solid electrolyte gas sensors
Publikation: Beitrag in Fachzeitschrift › Forschungsartikel › Beigetragen › Begutachtung
Beitragende
Abstract
A zirconia-based potentiometric solid electrolyte gas sensor with internal solid state reference was used to study the response behavior of platinum cermet and indium tin oxide sensing electrodes. Target gases included both oxygen and carbon monoxide in nitrogen-based sample gas mixtures. It was found that with the indium tin oxide sensing electrode, the low-temperature behavior is mainly a result of incomplete equilibration due to contaminations of the electrode surface. On the other hand, some of these contaminant species have been identified as being pivotal for the higher carbon monoxide sensitivity of the indium tin oxide sensing electrode as compared to platinum cermet electrodes.
Details
| Originalsprache | Englisch |
|---|---|
| Aufsatznummer | 2345 |
| Fachzeitschrift | Sensors |
| Jahrgang | 21 |
| Ausgabenummer | 7 |
| Publikationsstatus | Veröffentlicht - 1 Apr. 2021 |
| Peer-Review-Status | Ja |
Externe IDs
| PubMed | 33801748 |
|---|
Schlagworte
ASJC Scopus Sachgebiete
Schlagwörter
- Indium tin oxide, Internal reference gas sensor, Mixed potential, Potentiometric solid electrolyte sensor