In addition to the previously reported experimental results on post-tensioned glass beams, the current paper discusses the results of exploratory bending experiments on 2 series of structural glass beams which are pre­stressed by externally bonded tendons. These tendons - stainless steel or CFRP - are pre-tensioned and subsequently adhesively bonded to the lower edge of the glass beams by means of a two-component epoxy adhesive (3M DP 490). After curing, the pre-stressed glass beams are tested in four-point bending and their results are compared with the experimental results of reference beams without any tendons. From the results it is observed that pre-stressed glass beams demonstrate enhanced fracture strength compared to the reference beams. In addition, the pre-stressed glass beams show significant post-fracture load­carrying capacity. From the study it is concluded that pre-stressing a glass beam with externally bonded tendons is a feasible concept. However, more in depth studies to validate the concept are needed.

Details

OriginalspracheEnglisch
TitelGlassCon Global Conference Proceedings
Herausgeber (Verlag)GlassCon Global
Seiten460-469
PublikationsstatusVeröffentlicht - 2014
Peer-Review-StatusJa

Schlagworte

Forschungsprofillinien der TU Dresden

Fächergruppen, Lehr- und Forschungsbereiche, Fachgebiete nach Destatis

Ziele für nachhaltige Entwicklung

Schlagwörter

  • structural glass beams, pre-stressing, redundancy, experiment