Residual Generator based Measurement of the Current Input into a Cell
Publikation: Beitrag in Fachzeitschrift › Forschungsartikel › Beigetragen › Begutachtung
Beitragende
Abstract
We address the problem of real-time estimation of the excitation current into a cell. The membrane voltages can be measured experimentally, even in vivo. On the other hand, a direct measurement of the current into a cell interferes with the voltage activity. We propose a method to estimate the current input into a cell using the measured voltage and an observer based residual generator scheme. Our approach can be applied to all cell models of the Hodgkin-Huxley type.
Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 433-442 |
Seitenumfang | 10 |
Fachzeitschrift | Nonlinear Dynamics and Systems Theory |
Jahrgang | 9 |
Ausgabenummer | 4 |
Publikationsstatus | Veröffentlicht - 2009 |
Peer-Review-Status | Ja |
Externe IDs
Scopus | 74549197671 |
---|
Schlagworte
Schlagwörter
- Cell models, Nonlinear control, Observer, Residual generator