Qualitative computer aided evaluation of dental impressions in vivo

Publikation: Beitrag in FachzeitschriftForschungsartikelBeigetragenBegutachtung

Beitragende

  • Ralph G. Luthardt - , Universitätsklinikum Carl Gustav Carus Dresden, Poliklinik für Zahnärztliche Prothetik (Autor:in)
  • Rainer Koch - , Technische Universität Dresden, Institut für Medizinische Informatik und Biometrie (Autor:in)
  • Heike Rudolph - , Universitätsklinikum Carl Gustav Carus Dresden, Poliklinik für Zahnärztliche Prothetik (Autor:in)
  • Michael H. Walter - , Universitätsklinikum Carl Gustav Carus Dresden, Poliklinik für Zahnärztliche Prothetik (Autor:in)

Abstract

Objectives. Clinical investigations dealing with the precision of different impression techniques are rare. Objective of the present study was to develop and evaluate a procedure for the qualitative analysis of the three-dimensional impression precision based on an established in-vitro procedure. The zero hypothesis to be tested was that the precision of impressions does not differ depending on the impression technique used (single-step, monophase and two-step-techniques) and on clinical variables. Digital surface data of patient's teeth prepared for crowns were gathered from standardized manufactured master casts after impressions with three different techniques were taken in a randomized order. Data-sets were analyzed for each patient in comparison with the one-step impression chosen as the reference. The qualitative analysis was limited to data-points within the 99.5%-range. Based on the color-coded representation areas with maximum deviations were determined (preparation margin and the mantle and occlusal surface). To qualitatively analyze the precision of the impression techniques, the hypothesis was tested in linear models for repeated measures factors (p<0.05). For the positive 99.5% deviations no variables with significant influence were determined in the statistical analysis. In contrast, the impression technique and the position of the preparation margin significantly influenced the negative 99.5% deviations. The influence of clinical parameter on the deviations between impression techniques can be determined reliably using the 99.5 percentile of the deviations. An analysis regarding the areas with maximum deviations showed high clinical relevance. The preparation margin was pointed out as the weak spot of impression taking.

Details

OriginalspracheEnglisch
Seiten (von - bis)69-76
Seitenumfang8
FachzeitschriftDental Materials
Jahrgang22
Ausgabenummer1
PublikationsstatusVeröffentlicht - Jan. 2006
Peer-Review-StatusJa

Externe IDs

PubMed 16040117

Schlagworte

Schlagwörter

  • 3D-measurements, Computer aided analysis, Digitizing, One-step-impression, Optical measurement, Randomized controlled trial, Two-step-impression