Influence Of Measurement Setup on the Emission of Devices in the Frequency Range 2-150 KHz

Publikation: Beitrag in Buch/Konferenzbericht/Sammelband/GutachtenBeitrag in KonferenzbandBeigetragenBegutachtung

Beitragende

Abstract

The influence of measurement setup on the waveform distortion between 2-150 kHz (Supraharmonics) is analysed in this paper using a laboratory setup. Different LED lamps are used to observe how emissions at supraharmonic range are affected when considering different power sources, network impedances and current sensors. A particular condition of network impedance modified the amplitude of emissions, whilst a particular condition of current sensor included additional emissions between 2-150 kHz. The identification of conditions where supraharmonic emissions are affected by measurement setup is a step forward to the development of reliable, standard procedures for assessing conducted power quality disturbances between 2-150 kHz.

Details

OriginalspracheEnglisch
Titel2019 IEEE Milan PowerTech
PublikationsstatusVeröffentlicht - Juni 2019
Peer-Review-StatusJa

Externe IDs

Scopus 85072312737
ORCID /0000-0002-9052-3838/work/142253636

Schlagworte