Inertance measurements by jet pulses in ventilated small lungs after perfluorochemical liquid (PFC) applications
Publikation: Beitrag in Fachzeitschrift › Forschungsartikel › Beigetragen › Begutachtung
Beitragende
Abstract
Perfluorochemical liquid (PFC) liquids or aerosols are used for assisted ventilation, drug delivery, lung cancer hyperthermia and pulmonary imaging. The aim of this study was to investigate the effect of PFC liquid on the inertance (I) of the respiratory system in newborn piglets using partial liquid ventilation (PLV) with different volumes of liquid. End-inspiratory (I in) and end-expiratory (Iex) inertance were measured in 15 ventilated newborn piglets (age < 12 h, mean weight 724 ± 93 g) by brief flow pulses before and 80 min after PLV using a PFC volume (PF5080, 3 M) of 10 ml kg-1 (N = 5) or 30 ml kg-1 (N= 10). I was calculated from the imaginary part of the measured respiratory input impedance by regression analysis. Straight tubes with 2-4 mm inner diameter were used to validate the equipment in vitro by comparison with the analytically calculated values. In vitro measurements showed that the measuring error of I was <5% and that the reproducibility was better than 1.5%. The correlation coefficient of the regression model to determine I was >0.988 in all piglets. During gas ventilation, Iin and Iex (mean ± SD) were 31.7 ± 0.8 Pa l-1 s2 and 33.3 ± 2.1 Pa l -1 s2 in the 10 ml group and 32.4 ± 0.8 Pa l -1 s2 and 34.0 ± 2.5 Pa l-1 s 2 in the 30 ml group. However, I of the 3 mm endotracheal tube (ETT) used was already 26.4 Pa l-1 s2 (about 80% of measured I). During PLV, there was a minimal increase of Iin to 33.1 ± 2.5 Pa l-1 s2 in the 10 ml group and to 34.5 ± 2.7 Pa l-1 s2 in the 30 ml group. In contrast, the increase of Iex was dramatically larger (p < 0.001) to 67.7 ± 13.3 Pa l-1 s2 and to 74.8 ± 9.3 Pa l-1 s 2 in the 10 ml and 30 ml groups, respectively. Measurements of I by jet pulses in intubated small animals are reproducible. PFC increases the respiratory inertance, but the magnitude depends considerably on its spatial distribution which changes during the breathing cycle. Large differences between Iin and Iex are an indicator for liquid in airways or the ETT.
Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 239-249 |
Seitenumfang | 11 |
Fachzeitschrift | Physiological measurement |
Jahrgang | 26 |
Ausgabenummer | 3 |
Publikationsstatus | Veröffentlicht - Juni 2005 |
Peer-Review-Status | Ja |
Externe IDs
PubMed | 15798299 |
---|
Schlagworte
Ziele für nachhaltige Entwicklung
ASJC Scopus Sachgebiete
Schlagwörter
- Forced oscillation technique, Inertance measurements, Jet pulses, Newborns, Partial liquid ventilation