In vivo effects of coating loaded and unloaded Ti implants with collagen, chondroitin sulfate, and hydroxyapatite in the sheep tibia

Publikation: Beitrag in FachzeitschriftForschungsartikelBeigetragenBegutachtung

Beitragende

  • Stefan Rammelt - , UniversitätsCentrum für Orthopädie, Unfall - und Plastische Chirurgie, Universitätsklinikum Carl Gustav Carus Dresden (Autor:in)
  • Christian Heck - , Universitätsklinikum Carl Gustav Carus Dresden, UniversitätsCentrum für Orthopädie, Unfall - und Plastische Chirurgie (OUPC) (Autor:in)
  • Ricardo Bernhardt - , Professur für Biomaterialien (Autor:in)
  • Susanne Bierbaum - , Professur für Biomaterialien (Autor:in)
  • Dieter Scharnweber - , Professur für Biomaterialien (Autor:in)
  • Jürgen Goebbels - , Bundesanstalt für Materialforschung und -prüfung (BAM) (Autor:in)
  • Jörg Ziegler - , UniversitätsCentrum für Orthopädie, Unfall - und Plastische Chirurgie (OUPC) (Autor:in)
  • Achim Biewener - , Universitätsklinikum Carl Gustav Carus Dresden, UniversitätsCentrum für Orthopädie, Unfall - und Plastische Chirurgie (OUPC) (Autor:in)
  • Hans Zwipp - , Universitätsklinikum Carl Gustav Carus Dresden, UniversitätsCentrum für Orthopädie, Unfall - und Plastische Chirurgie (OUPC) (Autor:in)

Abstract

The in vivo effects of coating titanium implants with organic extracellular matrix molecules were examined in the sheep tibia. Titanium screws (5.0 mm) were coated with type I collagen (Ti/Coll) or type I collagen and chondroitin sulfate (Ti/Coll/CS) by biomimetic fibrillogenesis. Uncoated screws (Ti) and screws coated with hydroxyapatite (Ti/HA) served as control. Six adult female sheep received one screw of each type to stabilize a midshaft tibial fracture with external fixation. Four cylindrical implants of4-mm outer diameter and 3.3-mm inner diameter with the same coatings were inserted into the tibial head. No pin track infections were seen at the time of implant retrieval 6 weeks after implantation. Extraction torque was greater for Ti/HA (1181 Nmm) and Ti/Coll/CS (1088 Nmm) compared to Ti/Coll (900 Nmm) and Ti (904 Nmm) [N.S.]. Newly formed bone was noted around all coated screws within the medullary cavity. Macrophage and osteoclast activity was significantly reduced around Ti/Coll/CS in both types of implants compared to uncoated controls (p < 0.05). Osteoblast activity was significantly increased around loaded Ti/Coll and Ti/Coll/CS screws compared to uncoated Ti screws (p <0.05). Microtomographic evaluation (SRμCT) revealed no significant differences in new bone formation around the unloaded tibial head implants. Coating of external fixation devices with of type I collagen and chondroitin sulfate appears to have similar effects with respect to stability and bone healing as HA but with less osteoclast activity. These findings were more pronounced under loaded than unloaded conditions in the sheep tibia.

Details

OriginalspracheEnglisch
Seiten (von - bis)1052-1061
Seitenumfang10
FachzeitschriftJournal of orthopaedic research
Jahrgang25
Ausgabenummer8
PublikationsstatusVeröffentlicht - Aug. 2007
Peer-Review-StatusJa

Externe IDs

PubMed 17457829

Schlagworte

ASJC Scopus Sachgebiete

Schlagwörter

  • Bone implants, Chondroitin sulfate, Coating, Collagen, External fixation, Titanium