In the framework of the refurbishment process of the Rijksmuseum Amsterdam, it is intended to provide an adequate internal insulation of the exterior facades, which increases indoor climate quality, ensures hygric durability and reduces heat losses. This contribution shows the suitability of a capillary active internal insulation in order to distribute the interstitial condensation and the penetrated rain water. Foam glass prevents the drying potentials and leads to the destruction of the brick wall.

Details

OriginalspracheEnglisch
TitelStructural Studies, Repairs and Maintenance of Heritage Architecture IX
Redakteure/-innenC.A. Brebbia, A. Torpiano
Seiten345-354
Seitenumfang10
PublikationsstatusVeröffentlicht - 2005
Peer-Review-StatusJa

Publikationsreihe

ReiheWIT Transactions on the Built Environment
Band83
ISSN1743-3509
ReiheAdvances in architecture series
Band20
ISSN1368-1435