Experimental neutronics tests for a neutron activation system for the European ITER TBM
Publikation: Beitrag in Buch/Konferenzbericht/Sammelband/Gutachten › Beitrag in Konferenzband › Beigetragen › Begutachtung
Beitragende
Abstract
We are investigating methods for neutron flux measurement in the ITER TBM. In particular we have tested sets of activation materials leading to induced gamma activities with short half-lives of the order of tens of seconds up to minutes and standard activation materials. Packages of activation foils have been irradiated with the intense neutron generator of Technical University of Dresden in a pure DT neutron field as well as in a neutronics mock-up of the European ITER HCLL TBM. An important aim was to check whether the gamma activity induced in the activation foils in these packages could be measured simultaneously. It was indeed possible to identify gamma lines of interest in gamma-ray measurements immediately after extraction from the irradiation.
Details
Originalsprache | Englisch |
---|---|
Titel | Fusion Reactor Diagnostics - Proceedings of the International Conference |
Herausgeber (Verlag) | American Institute of Physics Inc. |
Seiten | 175-178 |
Seitenumfang | 4 |
ISBN (Print) | 9780735412484 |
Publikationsstatus | Veröffentlicht - 2014 |
Peer-Review-Status | Ja |
Publikationsreihe
Reihe | AIP Conference Proceedings |
---|---|
Band | 1612 |
ISSN | 0094-243X |
Konferenz
Titel | International Conference on Fusion Reactor Diagnostics |
---|---|
Dauer | 9 - 13 September 2013 |
Stadt | Villa Monastero, Varenna |
Land | Italien |
Schlagworte
ASJC Scopus Sachgebiete
Schlagwörter
- activation foils, ITER TBM, Neutron activation system