This paper presents a study on the development of a bonded edge seal for fluid-filled insulating glass units. Such novel façade elements enable multifunctional building envelopes and an improved energy efficiency of buildings. The bonded edge seal of a fluid-filled glazing is highly stressed due to the hydrostatic pressure that acts in addition to typical loads on façades. The permanent exposure to the fluid may also cause severe aging effects. Therefore, the edge seal is designed in such a way that the chemical and physical stress splits on two functional zones. The first functional zone serves as a protective seal and separates the fluid from the second, load-bearing functional zone. The adhesives for both functional zones were selected using an extensive test program.
Once the materials have been selected, the novel façade elements are tested in large scale component tests. The mock-ups are built on a scale of 1:2 compared to the original size of the intended façade elements. Since the study focuses on the performance of the adhesively bonded edge, the edge detail is realized in original size while the glass size is smaller. The glass thickness is modified to achieve rotations in the edge zone that correspond to façade elements in original size. The tests are performed in a test rig for curtain walls, which allows the simultaneous loading of the element by cyclic wind pressure and constant water pressure. The adhesive bond carries all the loads except the deadweight of the glass panes. The test results allow prediction of serviceability limit state and ultimate limit state.
Once the materials have been selected, the novel façade elements are tested in large scale component tests. The mock-ups are built on a scale of 1:2 compared to the original size of the intended façade elements. Since the study focuses on the performance of the adhesively bonded edge, the edge detail is realized in original size while the glass size is smaller. The glass thickness is modified to achieve rotations in the edge zone that correspond to façade elements in original size. The tests are performed in a test rig for curtain walls, which allows the simultaneous loading of the element by cyclic wind pressure and constant water pressure. The adhesive bond carries all the loads except the deadweight of the glass panes. The test results allow prediction of serviceability limit state and ultimate limit state.
Details
Originalsprache | Englisch |
---|---|
Titel | Challenging Glass Conference Proceedings, Volume 8, 2022 |
Redakteure/-innen | Jan Belis, Frek Bos, Christian Louter |
Publikationsstatus | Veröffentlicht - 2022 |
Peer-Review-Status | Nein |
Konferenz
Titel | Challenging Glass Conference 8 |
---|---|
Kurztitel | CGC |
Veranstaltungsnummer | 8 |
Dauer | 23 - 24 Juni 2022 |
Webseite | |
Bekanntheitsgrad | Internationale Veranstaltung |
Ort | Ghent University |
Stadt | Ghent |
Land | Belgien |
Externe IDs
ORCID | /0000-0003-1617-7399/work/142242014 |
---|---|
ORCID | /0000-0001-8585-0482/work/142250295 |
Schlagworte
Ziele für nachhaltige Entwicklung
ASJC Scopus Sachgebiete
Schlagwörter
- fluid-filled insulating glazing, bonded edge seal, component testing