Estimation of controlled attenuation parameter–based liver steatosis via raw ultrasound data from handheld devices

Publikation: Beitrag in FachzeitschriftForschungsartikelBeigetragenBegutachtung

Beitragende

Abstract

Purpose: Assessment of liver steatosis is primarily performed through visual evaluation during ultrasound examinations. A more objective approach relies on quantifying ultrasound attenuation, typically using devices such as the FibroScan® or elastography integrated into high-end ultrasound systems—which offer limited accessibility. By contrast, handheld ultrasound devices (HHUDs) are more affordable and widely available. Using raw ultrasound data to get deeper insights into liver tissue characteristics could turn HHUDs into valuable diagnostic tools. We hypothesized that the frequency-specific attenuation of raw ultrasound data acquired with handheld devices correlates with the controlled attenuation parameter (CAP) obtained through vibration-controlled transient elastography via FibroScan. Approach: In an exploratory, single-center study, raw data from 395 participants scheduled for CAP measurement were collected using HHUDs. Of these, 304 participants were included in the final analysis; 91 were excluded due to incomplete data. Using the raw data from the HHUDs, a method based on short-time fast Fourier transform was applied to calculate the frequency-specific attenuation. The results were then correlated with the CAP values. Results: Overall, the attenuation of the radiofrequency data showed a strong linear correlation with CAP values (r=0.672, p<0.001), although the strength of correlation varied significantly across frequencies (r_min = 0.443 at 0.75 MHz, r_max = 0.721 at 3.75 MHz), with the highest correlation, equaling results from studies with high-end ultrasound devices. Conclusion: HHUDs capable of acquiring raw data may serve as objective and accessible screening tools for liver steatosis, potentially improving treatment monitoring.

Details

OriginalspracheEnglisch
Aufsatznummer027001
FachzeitschriftJournal of Medical Imaging
Jahrgang13
Ausgabenummer2
PublikationsstatusVeröffentlicht - 1 März 2026
Peer-Review-StatusJa

Externe IDs

ORCID /0000-0002-3474-3115/work/215165069
ORCID /0000-0002-2421-6127/work/215165074
ORCID /0000-0002-0676-6926/work/215165138
ORCID /0009-0004-0685-2463/work/215166570
ORCID /0000-0001-5921-9478/work/215166579
ORCID /0009-0004-9063-5161/work/215166584
ORCID /0009-0002-1132-9787/work/215835749

Schlagworte

Schlagwörter

  • handheld ultrasound, liver imaging, liver steatosis, quantitative ultrasound