Electrical injury - a dual center analysis of patient characteristics, therapeutic specifics and outcome predictors

Publikation: Beitrag in FachzeitschriftForschungsartikelBeigetragenBegutachtung

Beitragende

  • Jochen Gille - , Klinikum St. Georg Leipzig (Autor:in)
  • Thomas Schmidt - , Berufs­­genossenschaften (BG) Klinikum Bergmannstrost (Autor:in)
  • Adrian Dragu - , UniversitätsCentrum für Orthopädie, Unfall - und Plastische Chirurgie, Klinikum St. Georg Leipzig (Autor:in)
  • Dimitri Emich - , Klinikum St. Georg Leipzig (Autor:in)
  • Peter Hilbert-Carius - , Berufs­­genossenschaften (BG) Klinikum Bergmannstrost (Autor:in)
  • Thomas Kremer - , Klinikum St. Georg Leipzig (Autor:in)
  • Thomas Raff - , Klinikum St. Georg Leipzig (Autor:in)
  • Beate Reichelt - , Berufs­­genossenschaften (BG) Klinikum Bergmannstrost (Autor:in)
  • Apostolos Siafliakis - , Berufs­­genossenschaften (BG) Klinikum Bergmannstrost (Autor:in)
  • Frank Siemers - , Berufs­­genossenschaften (BG) Klinikum Bergmannstrost (Autor:in)
  • Michael Steen - , Berufs­­genossenschaften (BG) Klinikum Bergmannstrost (Autor:in)
  • Manuel F. Struck - , Berufs­­genossenschaften (BG) Klinikum Bergmannstrost, Universität Leipzig (Autor:in)

Abstract

Background: Electrical injuries represent life-threatening emergencies. Evidence on differences between high (HVI) and low voltage injuries (LVI) regarding characteristics at presentation, rhabdomyolysis markers, surgical and intensive burn care and outcomes is scarce. Methods: Consecutive patients admitted to two burn centers for electrical injuries over an 18-year period (1998-2015) were evaluated. Analysis included comparisons of HVI vs. LVI regarding demographic data, diagnostic and treatment specific variables, particularly serum creatinine kinase (CK) and myoglobin levels over the course of 4 post injury days (PID), and outcomes. Results: Of 4075 patients, 162 patients (3.9%) with electrical injury were analyzed. A total of 82 patients (50.6%) were observed with HVI. These patients were younger, had considerably higher morbidity and mortality, and required more extensive burn surgery and more complex burn intensive care than patients with LVI. Admission CK and myoglobin levels correlated significantly with HVI, burn size, ventilator days, surgical interventions, amputation, flap surgery, renal replacement therapy, sepsis, and mortality. The highest serum levels were observed at PID 1 (myoglobin) and PID 2 (CK). In 23 patients (14.2%), cardiac arrhythmias were observed; only 4 of these arrhythmias occurred after hospital admission. The independent predictors of mortality were ventilator days (OR 1.27, 95% CI 1.06-1.51, p = 0.009), number of surgical interventions (OR 0.47, 95% CI 0.27-0.834, p = 0.010) and limb amputations (OR 14.26, 95% CI 1.26-162.1, p = 0.032). Conclusions: Patients with electrical injuries, HVI in particular, are at high risk for severe complications. Due to the need for highly specialized surgery and intensive care, treatment should be reserved to burn units. Serum myoglobin and CK levels reflect the severity of injury and may predict a more complex clinical course. Routine cardiac monitoring > 24 h post injury does not seem to be necessary.

Details

OriginalspracheEnglisch
Aufsatznummer43
FachzeitschriftScandinavian journal of trauma, resuscitation and emergency medicine
Jahrgang26
Ausgabenummer1
PublikationsstatusVeröffentlicht - 31 Mai 2018
Peer-Review-StatusJa

Externe IDs

PubMed 29855384
ORCID /0000-0003-4633-2695/work/145698714

Schlagworte

ASJC Scopus Sachgebiete

Schlagwörter

  • Amputation, Burns, Creatinine kinase, Electrical injury, High voltage, Myoglobin