BACKGROUND: Peritoneal dialysis-related peritonitis (PDRP) is the most common complication of peritoneal dialysis (PD), which can lead to poor outcomes if not diagnosed and treated early. We aimed to investigate the diagnostic accuracy of MMP-8 and IL-6-based point-of-care tests (POCTs) in diagnosing PDRP in PD patients.

METHODS: This retrospective chart review study was conducted at a comprehensive kidney center in Qatar. It involved all adult PD patients who underwent PDRP from July 2018 to October 2019 and for whom MMP-8 and IL-6-based POCTs were used to diagnose presumptive peritonitis. Measures of diagnostic accuracy were computed. Peritoneal fluid effluent analysis was the reference standard.

RESULTS: We included 120 patients (68 [56.7%] females, ages 55.6 ± 15.6 years, treatment duration 39.5 ± 30.4 months [range: 5-142 months]). In this population, MMP-8 and IL-6-based POCTs yielded 100% in all dimensions of diagnostic accuracy (sensitivity, specificity, positive and negative predictive values).

CONCLUSIONS: MMP-8 and IL-6-based POCTs might be helpful in the early detection of PDRP. This monocentric observation requires further confirmation in a prospective multicentric setting.