Compton imaging in a high energetic photon field

Publikation: Beitrag in Buch/Konferenzbericht/Sammelband/GutachtenBeitrag in KonferenzbandBeigetragen

Beitragende

  • T. Kormoll - , OncoRay - Nationales Zentrum für Strahlenforschung in der Onkologie, Professur für Kernphysik, Struktur- und Werkstoffmechanikforschung Dresden GmbH an der Technischen Universität Dresden (SWM) (Autor:in)
  • C. Golnik - , OncoRay - Nationales Zentrum für Strahlenforschung in der Onkologie, Struktur- und Werkstoffmechanikforschung Dresden GmbH an der Technischen Universität Dresden (SWM) (Autor:in)
  • S. Akhmadaliev - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • D. Bemmerer - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • J.V. Borany - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • F. Fiedler - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • F. Hueso Gonzalez - , Struktur- und Werkstoffmechanikforschung Dresden GmbH an der Technischen Universität Dresden (SWM) (Autor:in)
  • K. Heidel - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • M. Kempe - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • H. Rohling - , Struktur- und Werkstoffmechanikforschung Dresden GmbH an der Technischen Universität Dresden (SWM) (Autor:in)
  • K. Schmidt - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • S. Schöne - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • L. Wagner - , Professur für Kernphysik, Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • Guntram Pausch - , Struktur- und Werkstoffmechanikforschung Dresden GmbH an der Technischen Universität Dresden (SWM) (Autor:in)

Abstract

Through the well defined range of charged particles in matter, cancer irradiation by means of ions can be very tumor conformal. However, external range verification is needed to fully exploit the advantages of ion beam therapy. Nuclear interactions between the projectiles and targets result in excited nuclei which emit photons in the MeV energy range during deexcitation. With a Compton camera, it should be possible to image the origin of these photons which is correlated to the beam position. A prototype Compton camera comprising CdZnTe layers and scintillation detectors has been developed and tested with radioactive point sources. In this work, the performance of the camera is tested at a tandetron beam line in a clean radiation field of 4.44 MeV photons. It was shown that Compton imaging at this energy is feasible.

Details

OriginalspracheEnglisch
Titel2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)
Herausgeber (Verlag)IEEE Computational Intelligence Society (CIS)
Seiten1-3
Seitenumfang3
ISBN (Print)978-1-4799-3423-2
PublikationsstatusVeröffentlicht - 2 Nov. 2013
Peer-Review-StatusNein

Publikationsreihe

ReiheIEEE Symposium on Nuclear Science (NSS/MIC)
ISSN1082-3654

Konferenz

Titel2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC)
Dauer27 Oktober - 2 November 2013
OrtSeoul, Korea (South)

Externe IDs

Scopus 84904177199
ORCID /0000-0001-9023-3606/work/142252760

Schlagworte

Ziele für nachhaltige Entwicklung

Schlagwörter

  • Detectors, Photonics, Cameras, Image reconstruction, Germanium, Radiation effects