Comparison of hygrothermal 2D- and 3D-simulation results with measurements from a test house
Publikation: Beitrag in Fachzeitschrift › Konferenzartikel › Beigetragen › Begutachtung
Beitragende
Abstract
This article examines whether transient two-dimensional simulations are sufficient or three-dimensional simulations are necessary for the hygrothermal analysis of the three-dimensional detail of a beam support. Detailed measurement series from a test house with various interior insulation systems available for the investigation allow the results of two- and three-dimensional simulations to be verified with the measured data. In both the cases, a very good agreement between measurement and simulations was found. With the thermal simulations, agreement with the measured data is similar in both two- and three-dimensional calculations. However, the hygric measurements agreed slightly better with the three-dimensional calculations. For planning real tasks, two-dimensional simulations should be sufficient, provided that the simulation settings are selected within the secure margins. The actual comparison is initiated by the validation of the software DELPHIN 6 by means of a three-dimensional, stationary test case from EN 10211.
Details
Originalsprache | Englisch |
---|---|
Aufsatznummer | 08004 |
Fachzeitschrift | E3S Web of Conferences |
Jahrgang | 2020 |
Ausgabenummer | 172 |
Publikationsstatus | Veröffentlicht - 30 Juni 2020 |
Peer-Review-Status | Ja |
Konferenz
Titel | 12th Nordic Symposium on Building Physics |
---|---|
Kurztitel | NSB 2020 |
Veranstaltungsnummer | 12 |
Dauer | 7 - 9 September 2020 |
Ort | Tallinn University of Technology |
Stadt | Tallinn |
Land | Estland |