Capacity and Sizing of Wire Mesh Mist Eliminators at Critical Fluid Properties
Publikation: Beitrag in Fachzeitschrift › Forschungsartikel › Beigetragen › Begutachtung
Beitragende
Abstract
Wire mesh flooding point measurements at low surface tension < 10 mN m−1 were conducted using a refrigerant as model fluid. A new method for the calculation of wire mesh capacity was developed based on experimental data from literature and data from this study. In comparison to the well-known and widely adapted K-value method given in the Gas Processors Suppliers Association (GPSA) Engineering Databook and various other sources, the new method yields 3–38 % reduced wire mesh cross sections for fluid systems at pressures above 20 bar(a) while retaining an inherent safety margin.
Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 1166-1177 |
Seitenumfang | 12 |
Fachzeitschrift | Chemie-Ingenieur-Technik |
Jahrgang | 93 |
Ausgabenummer | 7 |
Publikationsstatus | Veröffentlicht - Juli 2021 |
Peer-Review-Status | Ja |
Extern publiziert | Ja |
Schlagworte
ASJC Scopus Sachgebiete
Schlagwörter
- Flooding point, K-value, Mist eliminator capacity, Wire mesh