Capacity and Sizing of Wire Mesh Mist Eliminators at Critical Fluid Properties

Publikation: Beitrag in FachzeitschriftForschungsartikelBeigetragenBegutachtung

Beitragende

  • Felix Flegiel - , Linde AG (Autor:in)
  • Christoph Windmeier - , Linde AG (Autor:in)
  • Michael Wiezorek - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • D. Alexander - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • Markus Schubert - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • Uwe Hampel - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)
  • Eckhard Schleicher - , Helmholtz-Zentrum Dresden-Rossendorf (Autor:in)

Abstract

Wire mesh flooding point measurements at low surface tension < 10 mN m−1 were conducted using a refrigerant as model fluid. A new method for the calculation of wire mesh capacity was developed based on experimental data from literature and data from this study. In comparison to the well-known and widely adapted K-value method given in the Gas Processors Suppliers Association (GPSA) Engineering Databook and various other sources, the new method yields 3–38 % reduced wire mesh cross sections for fluid systems at pressures above 20 bar(a) while retaining an inherent safety margin.

Details

OriginalspracheEnglisch
Seiten (von - bis)1166-1177
Seitenumfang12
FachzeitschriftChemie-Ingenieur-Technik
Jahrgang93
Ausgabenummer7
PublikationsstatusVeröffentlicht - Juli 2021
Peer-Review-StatusJa
Extern publiziertJa

Schlagworte

Schlagwörter

  • Flooding point, K-value, Mist eliminator capacity, Wire mesh