Assessing the agreement between the pneumatic and the flow-centrifuge method for estimating xylem safety in temperate diffuse-porous tree species

Publikation: Beitrag in FachzeitschriftForschungsartikelBeigetragenBegutachtung

Beitragende

  • S. S. Paligi - , Julius-Maximilians-Universität Würzburg (Autor:in)
  • R. M. Link - , Professur für Forstbotanik, Julius-Maximilians-Universität Würzburg (Autor:in)
  • E. Isasa - , Julius-Maximilians-Universität Würzburg (Autor:in)
  • P. Bittencourt - , University of Exeter (Autor:in)
  • J. S. Cabral - , Julius-Maximilians-Universität Würzburg, University of Birmingham (Autor:in)
  • S. Jansen - , Universität Ulm (Autor:in)
  • R. S. Oliveira - , Universidade Estadual de Campinas (Autor:in)
  • L. Pereira - , Universität Ulm (Autor:in)
  • B. Schuldt - , Professur für Forstbotanik, Julius-Maximilians-Universität Würzburg (Autor:in)

Abstract

The increasing frequency of global change-type droughts has created a need for fast, accurate and widely applicable techniques for estimating xylem embolism resistance to improve forecasts of future forest changes. We used data from 12 diffuse-porous temperate tree species covering a wide range of xylem safety to compare the pneumatic and flow-centrifuge method, two rapid methods used for constructing xylem vulnerability curves. We evaluated the agreement between parameters estimated with both methods and the sensitivity of pneumatic measurements to the duration of air discharge (AD) measurements. There was close agreement between xylem water potentials at 50% air discharged (PAD), estimated with the Pneumatron, and 50% loss of hydraulic conductivity (PLC), estimated with the flow-centrifuge method (mean signed deviation: 0.12 MPa, Pearson correlation: 0.96 after 15 s of gas extraction). However, the relationship between the estimated slopes was more variable, resulting in lower agreement in the xylem water potential at 12% and 88% PAD/PLC. The agreement between the two methods was not affected by species-specific vessel length distributions. All pneumatic parameters were sensitive to AD time. Overall agreement was highest at relatively short AD times, with an optimum at 16 s. Our results highlight the value of the Pneumatron as an easy and reliable tool to estimate 50% embolism thresholds for a wide range of diffuse-porous temperate angiosperms. Further, our study provides a set of useful metrics for methodological comparisons of vulnerability curves in terms of systematic and random deviations, as well as overall agreement.

Details

OriginalspracheEnglisch
Seiten (von - bis)1171-1185
Seitenumfang15
FachzeitschriftPlant biology
Jahrgang25
Ausgabenummer7
PublikationsstatusVeröffentlicht - Dez. 2023
Peer-Review-StatusJa

Externe IDs

PubMed 37703535
ORCID /0000-0003-0588-3757/work/170587658

Schlagworte

Schlagwörter

  • Drought tolerance traits, flow-centrifuge, method comparison, plant pneumatics, Pneumatron, transport, vulnerability curve, xylem embolism resistance