Adaptive wavefront shaping for flow-field measurements

Publikation: Beitrag in Buch/Konferenzbericht/Sammelband/GutachtenBeitrag in KonferenzbandBeigetragenBegutachtung

Beitragende

Abstract

In this contribution we use wavefront shaping approaches for image correlation based flow-field measurements for the first time. Aberrations introduced by a single phase boundary in the detection beam path were explored. Variations of the optical path-length result in strong errors in position allocation and thus to an enhancement of the measurement uncertainty of the velocity. Our results show that the usage of wavefront shaping enables to reduce these errors and to strongly improve the quality of image correlation based flow-field measurements. First experimental and simulated results underline the importance of these approaches.

Details

OriginalspracheEnglisch
TitelAdaptive Optics and Wavefront Control for Biological Systems II
Redakteure/-innenSylvain Gigan, Thomas G. Bifano, Joel Kubby
Herausgeber (Verlag)SPIE - The international society for optics and photonics
ISBN (elektronisch)9781628419511
PublikationsstatusVeröffentlicht - 2016
Peer-Review-StatusJa

Publikationsreihe

ReiheProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Band9717
ISSN1605-7422

Konferenz

TitelAdaptive Optics and Wavefront Control for Biological Systems II
Dauer13 - 15 Februar 2016
StadtSan Francisco
LandUSA/Vereinigte Staaten

Schlagworte

Schlagwörter

  • Adaptive optics, digital holography, flow-field measurements