1-Year Outcomes of Novel Balloon-Expandable vs Contemporary Transcatheter Heart Valves in Severe Aortic Stenosis: The LANDMARK Trial

Publikation: Beitrag in Fachzeitschrift › Forschungsartikel › Beigetragen › Begutachtung

Beitragende

  • LANDMARK Investigators - (Autor:in)
  • Klinik für Innere Medizin und Kardiologie (am Herzzentrum)
  • University Hospital Galway
  • Radboud University Medical Center
  • Instituto de Salud Carlos III
  • Hospital Clínico Universitario de Valladolid
  • Central Slovak Institute of Heart and Vascular Diseases
  • University Medical Centre Ljubljana
  • Amphia Hospital
  • North Estonia Medical Centre
  • Klinička bolnica Dubrava
  • Semmelweis University
  • Isala Klinieken Zwolle
  • European Interbalkan Medical Center Thessaloniki
  • Wrocław Medical University
  • St. Antonius Ziekenhuis
  • Hospital Universitario de Gran Canaria Doctor Negrín
  • Instituto Dante Pazzanese de Cardiologia
  • Universidade NOVA de Lisboa
  • Centre Hospitalier Universitaire (CHU) de Lille
  • IRCCS Ospedale Galeazzi - Sant'Ambrogio
  • Vita-Salute San Raffaele University
  • IRCCS San Raffaele Pisana - Roma
  • Auckland City Hospital
  • Hippokration General Hospital — Athens
  • Hôpital Henri Mondor
  • IRCCS Policlinico San Donato
  • Universitätsklinikum Utrecht
  • Hospital Universitario Reina Sofía
  • Maimónides Institute of Biomedical Research of Cordoba (IMIBIC)
  • CIBER - Enfermedades Cardiovasculares (CIBERCV)
  • Sahlgrenska University Hospital
  • Universitätsklinikum Gießen und Marburg GmbH
  • Kerckhoff Klinik
  • Universitätsklinikum Freiburg
  • Klinički Bolnički Centar (KBC) Split
  • Hospital Universitari Son Espases
  • Fundació Institut d'Investigació Sanitaria Illes Balears
  • East Lancashire Hospitals NHS Trust
  • University of Central Lancashire
  • Meril Life Sciences Pvt. Ltd.
  • Cardiovascular European Research Center (CERC)
  • Institut Cardiovasculaire Paris Sud
  • Hôpital privé Jacques-Cartier
  • Queen Mary University of London
  • Barts Health NHS Trust
  • Cleveland Clinic London

Abstract

BACKGROUND: In the LANDMARK trial, the Myval balloon-expandable transcatheter heart valve (THV) series was noninferior to the most commonly used contemporary SAPIEN and Evolut Series THVs for the 30-day early safety endpoint in participants with symptomatic severe native aortic stenosis.

OBJECTIVES: The current report from the LANDMARK trial describes clinical outcomes, hemodynamic performances, and quality of life at 1 year.

METHODS: This open-label, noninferiority trial enrolled 768 participants across 31 hospitals in Europe, New Zealand, and Brazil. Participants were randomly assigned (1:1) to receive either a Myval THV series or a contemporary THV (SAPIEN or Evolut series). The composite endpoint at 1 year included all-cause mortality, all strokes, and procedure- or valve-related hospitalizations. Clinical efficacy was defined as freedom from the composite endpoint. As recommended in Valve Academic Research Consortium-3, the previous composite endpoint combined with the assessment of quality of life at baseline and 1 year with the 12-Item Short Form Health Survey was reported as an extended composite endpoint. The noninferiority hypothesis was prespecified for the assessment of the primary endpoint at 30 days. Considering the specific 1-year composite endpoints of Valve Academic Research Consortium-3 and the event rate of 27.23% derived from recent studies, an a posteriori descriptive and exploratory noninferiority hypothesis was introduced with a noninferiority margin of 10.89%. The analysis was performed in the intention-to-treat population.

RESULTS: The mean age was 80 years, 48% were women, and the median Society of Thoracic Surgeons Predicted Risk of Mortality score was 2.6%. There was no significant difference in the Kaplan-Meier estimates of freedom from the composite endpoint at 365 days (Myval THV 87.0% vs contemporary THVs 86.9%). The Myval THV series was noninferior to the contemporary THVs for the composite endpoint (difference: -0.1%; 1-sided 95% CI: 3.9%; Pnoninferiority < 0.0001). Similarly, there were no significant differences in freedom from the extended composite endpoint (80.5% vs 77.3%; difference: 3.2%; 95% CI: -2.9% to 9.2%; P = 0.33).

CONCLUSIONS: In the treatment of symptomatic severe native aortic stenosis, the clinical and hemodynamic outcomes of the Myval THV series were comparable to those of contemporary THVs for the 1-year composite of all-cause mortality, all strokes, or procedure- or valve-related hospitalizations. (LANDMARK Trial: a Randomised Controlled Trial of Myval THV [LANDMARK]; NCT04275726).

Details

OriginalspracheEnglisch
Seiten (von - bis)362-381
Seitenumfang20
FachzeitschriftJournal of the American College of Cardiology
Jahrgang87
Ausgabenummer4
Frühes Online-Datum16 Nov. 2025
PublikationsstatusVeröffentlicht - 3 Feb. 2026
Peer-Review-StatusJa

Externe IDs

Scopus 105024734737

Schlagworte

ASJC Scopus Sachgebiete

Schlagwörter

  • Evolut, Myval, SAPIEN, randomized controlled trial, transcatheter aortic valve replacement